Tag register

TagTypeSubsystemDescriptionDisciplineAreaCompanyLoopRangeSignalI/OP&IDCalibration dueRated power
10-P-1001ACentrifugal pump10-01Feed pump AMechanicalUnit 10Apex MechanicalPID-10-00155 kW
10-PM-1001AElectric motor10-01Feed pump A motorElectricalUnit 10Volt ElectricalPID-10-00155 kW
10-PT-1001Pressure transmitter10-01Feed pump discharge pressureInstrumentationUnit 10Volt ElectricalL-10010–25 barg4–20 mAAIPID-10-0012027-06-30
10-FV-1002Control valve10-01Feed flow control valveInstrumentationUnit 10Volt ElectricalL-10020–100 %4–20 mAAOPID-10-001
10-SWB-01Switchboard10-02LV switchboard 1ElectricalSubstation 1Volt Electrical
10-L-1001Piping line10-01Pump discharge linePipingUnit 10Apex MechanicalPID-10-001

What's inside

  • All the columns SureCon imports, in the right order
  • Six example tags across mechanical, electrical, instrumentation and piping
  • Extra columns (e.g. Rated power) become technical data on the tag

How to use it

  1. 1Keep the header row; replace the example tags with yours.
  2. 2Tag, Type and Subsystem are required on every row.
  3. 3Use the tag types listed on this page to get check sheets automatically.
  4. 4In SureCon: Tags → Import CSV. Re-importing updates existing tags.

Tag types SureCon recognises

Use these in the Type column and each tag gets its check sheets automatically.

  • Centrifugal pump
  • Electric motor
  • Pressure transmitter
  • Flow transmitter
  • Control valve
  • Switchboard
  • Piping line
  • Storage tank
  • Transformer
  • Power cable
  • Earthing system
  • Heat tracing circuit
  • Lighting circuit
  • Fire & gas detector
  • Pressure safety valve
  • Manual valve
  • HVAC unit
  • Duct
  • Foundation
  • Steel structure
  • Telecom device

Questions

Which columns are required?

Tag, Type and Subsystem. Everything else is optional, and any extra column becomes technical data on the tag.

Which tag types does SureCon recognise?

Centrifugal pump, Electric motor, Pressure transmitter, Flow transmitter, Control valve, Switchboard, Piping line, Storage tank, Transformer, Power cable, Earthing system, Heat tracing circuit, Lighting circuit, Fire & gas detector, Pressure safety valve, Manual valve, HVAC unit, Duct, Foundation, Steel structure, Telecom device. Each gets its check sheets and deliverables automatically.

Mechanical completion and handover, worked out from your records

Same layout, but on a phone, with photos, sign-offs and live progress for the whole team. Free, with unlimited users.