Sample project
Small LNG plant: Coral Bay Small-Scale LNG
A 0.3 MTPA small-scale LNG plant getting ready for start-up. Feed gas is metered and treated, liquefied in a mixed-refrigerant cold box, then stored and loaded onto trucks. The sample shows systemised completions: tags, check sheets and punch items rolled up into mechanical completion, ready for commissioning and ready for start-up certificates, with preservation on the rotating equipment.

- systems
- 5
- subsystems
- 10
- punch items
- 12
- companies
- 4
Systems and subsystems
10 · Feed gas & pre-treatment
- 10-01 Inlet metering & filtration
- 10-02 Amine unit (CO2 removal)
20 · Liquefaction
- 20-01 Mixed refrigerant compressor
- 20-02 Cold box & cryogenic exchanger
30 · LNG storage & loading
- 30-01 LNG storage tank
- 30-02 Truck loading bays
40 · Flare & safety systems
- 40-01 Flare & knockout drum
- 40-02 Fire & gas detection
50 · Utilities
- 50-01 Instrument air
- 50-02 Power generation
Companies and crews
- Coral Bay Energy · client
- Meridian Process Contractors · contractor
- Ironbark E&I · contractor
- Cryo Insulation Services · subcontractor
- Mechanical crew
- E&I crew
- Commissioning team
- Client QA
Also inside
- Over 40 punch items, most linked to tags, with history and a walkdown
- Drawings (P&IDs, single line and loop diagrams, layouts) with punch items pinned on them
- Specifications, procedures, datasheets and turnover documents as PDFs, with revisions
- A library with the scope of work, basis of design, execution plan and project plans
- Weekly report, punch analysis, commissioning status and management dashboard (PDF)
- Punch, document, submittal, action, commissioning and materials trackers (Excel)
- Tag register with technical data
- Check sheets for construction, pre-commissioning and commissioning
- ITPs, inspections and surveillance
- NCRs with corrective actions
- Technical queries and changes (MOC)
- Preservation routines
- Document register and transmittals
- MC, RFC, RFSU and handover certificates
- Daily logs with crews, equipment and weather
- Meetings with minutes and open actions
- Submittals under review, and the spec sections that need them
- Cable, piping and equipment schedules with progress
- Permits, LOTO, JSAs, risks and safety observations
- Issues, tasks, materials, purchase orders and vendors
- Commissioning activities, certifications and crews
- A site induction course with a quiz
Punch items you'll find
Written the way site teams write them, each with a category, discipline, crew, company and due date.
| Cat | Issue | Discipline | Company | Status |
|---|---|---|---|---|
| A | PSV-4105 set pressure certificate not provided | Piping | Meridian Process Contractors | Open |
| A | Vapour barrier damaged on cryogenic line 20-L-2214 insulation | Mechanical | Cryo Insulation Services | Open |
| A | MR compressor lube oil flushing record not signed off | Mechanical | Meridian Process Contractors | Ready to verify |
| A | Gas detector GD-4012 doesn't cover loading bay 2 as shown on the F&G layout | Instrumentation | Ironbark E&I | Open |
| A | Loading arm emergency release coupling test outstanding | Mechanical | Meridian Process Contractors | Open |
| B | Static earthing clamp on bay 1 not proving earth to the interlock | Electrical | Ironbark E&I | Ready to verify |
| B | Bolt torque record missing for flange on amine reboiler outlet | Piping | Meridian Process Contractors | Open |
| B | Heat tracing HT-1102 insulation resistance below 20 MΩ | Electrical | Ironbark E&I | Open |
Things to try
- 1See which subsystems are ready for mechanical completion and which punch items block RFSU.
- 2Open a pressure safety valve tag and check its datasheet and certificates.
- 3Look at preservation routines on the compressor and pumps, and what's overdue.
- 4Answer an open technical query and see it linked to the tag.
Ready in seconds, and free
Create a free account and the small lng plant sample opens straight away. No credit card. Delete it whenever you like, then set up your own project.
How SureCon helps oil & gas projects →Other sample projects

Small data centre
A 4 MW data hall: HV power, generators, UPS, chillers and CRAH units through Level 1–5 commissioning.
10 subsystems · 12 punch items · tags, check sheets, ITPs, NCRs and certificates
See what's inside
Small mining plant
A 1.5 Mtpa gold plant: crushing, grinding, CIL leach, tailings and power, from construction to wet commissioning.
10 subsystems · 12 punch items · tags, check sheets, ITPs, NCRs and certificates
See what's inside
Pump station
A small water pump station: pump skids, LV switchboard and motor control centre.
4 subsystems · 10 punch items · tags, check sheets, ITPs, NCRs and certificates
See what's inside