Tools
Run piping test packs and weld maps
Build a test pack, track its welds to acceptance, and test, reinstate and close it.

- 1
Create the pack
Test packs → New test pack. Give the pack number, subsystem, line numbers and isometrics, the test type and the design pressure. SureCon suggests the test pressure (1.5 × design for hydrotests, 1.1 × for pneumatic) before temperature correction.
- 2
Add the welds
Add welds and paste rows from your weld log: ISO, line, weld number, size, schedule, material, joint, shop or field, welder, WPS, date, visual, NDE method and result. Welds already on the map are updated, not duplicated.
- 3
Record results
Set visual and NDE results in the weld table. A rejected weld shows Repaired: use it once it's cut out and rewelded, and it goes back for inspection with its repair count.
- 4
Tick the readiness checks
Each stage lists what must be done first: limits marked on current P&IDs and isometrics, walkdown done, category A punch cleared, gauges calibrated, relief valve fitted, isolations, blinds, vents and drains, and the permit to work.
- 5
Move it on
Move to the next stage when the blockers are cleared. Record the test date, result and witnesses; an admin or inspector signs off Tested and Closed. Moving a pack back is always allowed.
- 6
Browse weld maps
Weld maps lists every weld on the project. Filter by state, NDE method, pack or welder, check welder repair rates and export to Excel.